Type-specific detection of herpes simplex virus type 1 and type 2 using the cobas® HSV

Analytical performance of AHSV was evaluated using test panels consisting of laboratory strains of HSV-1 and 2 and a variety of non-target human DNA viruses. Accurate HSV detection and typing are important for management, and molecular methods are considered the methods of choice (5–10). Here we demonstrate that a combination of proliferation and ELISPOT assays can be used to quantify and characterize effecter function of virus-specific immune memory responses during HSV-latency. Restriction enzyme cleavage analysis with Hpa II further permitted reliable distinction between VZV, HSV-1, and HSV-2. Detection of HSV-2 was similar, with a sensitivity of 98.9% and a specificity of 95.5%. Crossing-point (Cp) and melting-temperature (Tm) analyses were determined by the manufacturer’s software. The features and performance characteristics of the cobas 4800 HSV1 and HSV2 Test (cobas HSV) on the cobas 4800® system (cobas 4800) are described in detail.

Overall, 91 (30.3%) specimens were positive and 204 (68.0%) specimens were negative for HSV by both LightCycler assays. The sensitivity of real-time HSV-2 PCR was found to be 87% (33/38) in primary and 70% (19/27) in recurrent meningitis. Reactivations are triggered by endogenous and exogenous factors. Adsorption of rat-anti-HSV-2 serum with tREF-G-2 or rat fibrosarcoma cells reduced neutralizing activity to 10 and 12%, respectively, compared with 90% neutralization by antiserum adsorbed with nontransformed rat embryo fibroblast cells and 100% neutralization with unadsorbed antiserum. When HSV-2 probes were incubated with latently infected ganglion sections, hybridization was detected in 71% of guinea pigs and 46% of ganglia. The real-time PCR assay showed good specificity for detection and typing of HSV, with good linear range (5×102~5×108 copies/ml, r=0.997), a sensitivity of 5×102 copies/ml, and good reproducibility (intra-assay coefficients of variation 2.29% and inter-assay coefficients of variation 4.76%). Intraocular anti-HSV antibody production was detected in 9/28 AH samples tested (32%).


Comparison of LightCycler PCR (LC-PCR) with rapid antigen EIA and culture amplified detection of Herpes simplex virus in 262 specimens. The recurrence may be caused by different kinds of traumas, such as fever or physiological changes and diseases. Clin. To evaluate the analytical and clinical performance of the IsoAmp® HSV assay as well as the robustness and reproducibility of the assay. Cervical cancer can be cured if detected at an early stage. RESULTS: Cases from all groups were found to be positive for HSV-1 by PCR. Clinical specificity of AHSV for HSV-1 and 2 detection was 97.8% (95% CI: 96.3-98.8) and 94.5% (95% CI: 92.2-96.1), respectively, compared to culture; and 99.5% (95% CI: 98.5-99.9) and 99.5% (95% CI: 98.3-99.7), respectively, compared to culture with discordant resolution.

The Euroline scanner and computer program called each sample positive, borderline, or negative. The 7 samples showed the presence of both types of DNA herpes simplex virus, and 7 others were found for both HSV-1 and HSV-2 negative.Obtained results show that the designed method is highly specific and can possibly be used to simultaneously detect and differentiate HHV-1/2. Under ZPC-EM conditions, we were able to reconstruct an icosahedral map (Fig. In the event that diagnosis and treatment have been based in primary care, arrange follow-up: arrange an appointment at a genitourinary medicine (GUM) clinic in 2 to 3 weeks to allow patient education and a full STI screen. Eye tissue specimens from 12 donors who were or were not viremic and were or were not seropositive were investigated. The Euroline scanner and computer program called each sample positive, borderline, or negative. Peckham has had genital herpes for six years now and got it from an ex-girlfriend who didn’t know she had it.

I was hoping someone would go on ahead and call me out on that one, so I wouldn’t have to live in secret shame any longer. among others. For example, you think are your annual medical control tests for sexually transmitted diseases, especially if your doctor knows who are sexually active. Moreover, these tests can be expensive; False positives can occur in some individuals with a low probability of infection; and diagnosis can have negative psychological effects for some people. Papanicolaou-stained cervicovaginal smears from six patients with herpes simplex virus (HSV) infection were destained and reprocessed by means of in situ hybridization (ISH) technique to demonstrate the presence of HSV DNA utilizing biotinylated probe. 2 (1979), pp. Previous studies showed that SPL7013 has similar potency against CXCR4-(X4) and CCR5-using (R5) strains of HIV-1 and that it blocks viral entry.

• Improve your breathing without a breathing aid. However it is recommended that a one Detection Of Herpes Simplex Virus In Gingival Tisue time application of DNA in cells. Madrid, Spain) donated HSB-2 cells from Type T lymphocytes of acute lymphoblastic leukaemia. Among them, 26 empty capsids were all approximately 40nm from NPCs and 15 capsids with viral DNA inside were all more than 80 nm from NPCs. Asymptomatic-infected people shed herpes virus only about half as often as do people who have herpes symptoms.